ENGLISH
User calibration
With fixed reference points
0 point / 1/3 load / Max. load
Switch the scale off. Switch the scale on.
Press the and keys and hold for 2 sec. during
power-on.
Empty the scale and confirm the zero point by pressing .
Place the default weight on the scale (1/3 load) and con-
firm by pressing ..
Place the default weight on the scale (Max. load) and
confirm by pressing .
Empty the scale.
The scale goes to weighing mode.
Nullstellen
With variable reference point
0 point Test weight < Max
Switch the scale off. Switch the scale on.
Press the and keys and hold for 2 sec. when
switching on.
Empty the scale and confirm the zero point by pressing
the key.
You can toggle between the decades by pressing the
and keys.
You can increment the numerical value by pressing the
key.
Enter the existing weight, e.g. 6kg, and confirm by pres-
sing .
Place the existing weight on the scale and confirm by
pressing .
Empty the scale.
The scale goes to weighing mode.